Hot Runner Nozzle’s Cable Location Shifted
Hasco has extended its Vario Shot nozzle range and optimized its cable location.
Hasco has expanded its line Vario Shot hot runner nozzles and developed a version where the cable outlet has been moved to the middle of the nozzle, relocating it outside the hot half in the nozzle retainer plate.
From a maintenance standpoint, this optimized cable location allows the heater to be easily replaced while the mold is in the press. In the case of multi-cavity hot runner molds or needle valve applications, processors will no longer need to dismantle the hot runner and remove the needle during service. Hasco notes that the hot runner nozzle’s thermocouple can be replaced from the parting plane. Through a strategically placed groove in the heater’s brass body, the thermocouple can be easily dismantled and mounted again.

Hasco has shifted the cable location for its Vario Shot hot runner nozzles, easing maintenance.
Related Content
-
Interchangeable Needle Valve Pre-Chamber Simplifies Hot Runner’s Maintenance
Hasco’s Vario Shot Xgate features an interchangeable needle-valve pre-chamber to lower the cost and difficulty of maintenance.
-
RFID Applied to Hot Runner Systems
Hasco says the adapted variant of the Mold Tag makes it possible to read out all data on the hot half or a wired system directly on a smartphone.
-
Construction Begins on Fully Automated Hot Runner Production Plant
Oerlikon HRSflow will start the construction of a new fully automated plant in San Polo di Piave, Italy, to expand capacity for the growing European market.