Cut Material Waste With Accurate Gauge Measurement

Gauge control done right can save you big money on materials and improve quality to boot.

Paul Waller, Plastics Touchpoint Group

Share

Almost every film extrusion facility has mechanical devices to measure gauge variation. In many cases, the results differ from one device to the next, making it difficult to ascertain which one is correct. Operators need accurate information during setup to make sure the film gauge is within tolerance. They often overcompensate, making the film too thick in the beginning of a production run, and then adjusting after the first set of rolls is weighed. This strategy reduces yield and profit margins.

A common strategy to compensate for unreliable film gauge micrometers is to estimate the average thickness using the weight of a measured surface area of film (basis-weight technique) or the weight of a roll and core. Accuracy is limited because of possible variations in surface area of the film, concentration of ingredients (especially masterbatches), weight of the core, and length of film on the roll. Assumptions about the density of the various ingredients may be inaccurate. When this strategy is used to estimate average film gauge, mechanical film micrometers are relegated to the task of measuring thickness variation, not average film thickness.

Mechanical film micrometers are constructed with a fixed anvil and a moveable contact foot (see Fig. 1). For film applications, the moveable contact foot usually has a flat surface. There are three common causes for errors: incorrect contact pressure, presence of dirt, and misalignment between the anvil and contact foot.

Simple mechanical film micrometers rely on gravity to apply the correct contact pressure between the anvil and contact foot. More advanced systems use air pressure to do the same thing. Too much contact pressure compresses the film, giving readings that are thinner than the actual film. Operators often pull the film to the next measuring point while the contact foot rests on the film surface. This practice can bend the supporting rod, causing it to stick within the guiding cylinder. This will result in insufficient contact pressure, resulting in thicker-than-actual readings. In extreme cases, the contact foot cannot hold the film in position when it is lowered to the measuring position.
 

CLEANING & RECALIBRATION
 

Extrusion and converting facilities are dusty environments. Film-thickness micrometers are precision instruments that can detect the presence of dust and provide inconsistent measurements. Operators often resort to measuring the same point two or three times, a technique known as “stamping,” to obtain consistent thickness readings. This takes extra time and can compress the film, resulting in thinner-than-actual readings.

To clean the measuring surfaces, insert a piece of paper between the anvil and the contact foot. Then allow the contact foot to press the paper against the anvil, as if to measure the paper thickness. Pull the paper slowly about 5 cm (2 in.) while the contact foot is in the measuring position. Raise the contact foot and remove the paper. Bring the contact foot into contact with the anvil and recalibrate the micrometer to display zero thickness. Test the accuracy by raising and lowering the contact foot three or four times.

Measurement results should be between 0 and ±1 micron (±0.04 mils). If results vary more than this amount, try cleaning the measuring surfaces with a cotton swab soaked in alcohol and repeat the recalibration procedure. If measurement error persists, perform the parallelism procedure described in the next section.


PARALLEISM TEST & ADJUSTMENT


The anvil and flat surface of the contact foot must be parallel to within 1 micron (0.04 mils) to maintain accurate resolution for most mechanical micrometers. A parallelism wire gauge of 0.25 to 0.50 mm (0.01 to 0.02 in.) diam. is required for this test. If the instrument has a digital display, turn it on and wait at least 30 minutes for it to warm up before you begin.

Place the wire gauge on the anvil and lower the contact foot using standard pressure. The distance from the outside edge of the contact foot to the wire gauge should be no more than 3 mm (1/8 in.). Compare the measurements in all four positions as shown in Fig. 2. The film micrometer must be adjusted if the difference between opposite sides (front vs. back, left vs. right) is more than 1 micron (0.04 mils).

Some film micrometers have anvils that can be accurately repositioned. Another option is to use very fine sandpaper to make the measuring surface of the contact foot parallel to the anvil. This technique is known as lapping. Bent supporting rods cannot be repaired and must be replaced.
One point of view is that accurate measurement of film-gauge variations is not important because gauge variation cannot be eliminated, only tolerated. Companies that follow this strategy are doomed to low margins because they give away raw material.

Process Cooling

Related Content

Sponsored

Reduce Downtime and Scrap in the Blown Film Industry

The blown film sector now benefits from a tailored solution developed by Chem-Trend to preserve integrity of the bubble.

Read More

What You Need to Know About Roll-Cooling Design

Cooling rolls might not look like high-tech machines, but the fact is there is a surprising amount of technology involved in their design, manufacture and use. Here’s what you need to know.    

Read More
Sheet Extrusion

How to Decrease the Extrudate Temperature in Single-Screw Extruders

In many cases, decreasing the discharge temperature will improve product quality and perhaps even boost rate. Here are ways to do it.

Read More
Film Extrusion

Film Extrusion: Boost Mechanical Properties and Rate of Composting by Blending Amorphous PHA into PLA

A unique amorphous PHA has been shown to enhance the mechanical performance and accelerate the biodegradation of other compostable polymers PLA in blown film.

Read More

Read Next

sustainability

Lead the Conversation, Change the Conversation

Coverage of single-use plastics can be both misleading and demoralizing. Here are 10 tips for changing the perception of the plastics industry at your company and in your community.

Read More
best practices

People 4.0 – How to Get Buy-In from Your Staff for Industry 4.0 Systems

Implementing a production monitoring system as the foundation of a ‘smart factory’ is about integrating people with new technology as much as it is about integrating machines and computers. Here are tips from a company that has gone through the process.

Read More
NPE

Beyond Prototypes: 8 Ways the Plastics Industry Is Using 3D Printing

Plastics processors are finding applications for 3D printing around the plant and across the supply chain. Here are 8 examples to look for at NPE2024.

Read More